Practice 02

Power that holds the rack up, network that fills it

ByteHaul supplies the Huawei Digital Power UPS range and the Huawei eKit branch portfolio — the two halves of an ELV installation that are usually bought from two different suppliers, on two different lead times, with two different warranty processes.

Huawei Digital Power — UPS

From a branch comms cabinet to a modular data centre hall

One family, one service organisation, one battery strategy. We size the unit against your real load profile and required runtime — not against a catalogue page.

UPS families we supply — indicative positioning
Series Typical capacity Form factor Where it fits
UPS2000-A 1 – 10 kVA Tower / rack Comms cabinets, branch offices, access-control and CCTV racks, small server rooms.
UPS2000-G 1 – 20 kVA Tower / rack Edge and telecom sites, clinic and retail back rooms, small data rooms with growth.
UPS5000-A 30 – 600 kVA Tower Small to medium data centres, telecom rooms and financial branch infrastructure.
UPS5000-E 30 – 800 kVA Modular Medium data centres and critical infrastructure that must scale module by module.
UPS5000-H High density Modular Dense halls where footprint per kW is the deciding factor.
SmartLi / SmartLi Mini Lithium cabinet Battery Replacing lead-acid strings — longer life, smaller footprint, per-module management.
PDU8000 Rack PDU Distribution Rack-level power distribution and metering downstream of the UPS.

Capacities are indicative of each series and vary by model and configuration. We confirm the exact rating, battery type and options against the current datasheet in your quotation.

Modular where growth is unknown

If the hall will be filled over three years, a modular frame with installed modules beats a monolithic UPS sized for day one — you pay for capacity when it is commissioned, and maintenance happens module by module instead of a full shutdown.

Lithium where footprint is tight

SmartLi cabinets trade the lead-acid battery room for a managed lithium cabinet with module-level monitoring. It changes the floor plan, the cooling load and the replacement cycle — we model all three before quoting.

Monitored, not just installed

SNMP and Modbus interfaces into your BMS or DCIM, alarm mapping agreed at commissioning, and a documented escalation path so an alarm means something to someone.

Pre-sales engineering

How we size a UPS — and what we ask you for

A UPS quoted from a load figure alone is a guess. Send us these five inputs and the quotation comes back defensible.

  1. Connected load & diversity

    Rated kW of the IT and ELV loads plus the diversity you actually expect — not the sum of every nameplate.

  2. Runtime at full and partial load

    Battery autonomy required for generator start, orderly shutdown, or both — stated separately.

  3. Redundancy

    N, N+1 or 2N, and whether that redundancy is inside one frame or across two independent paths.

  4. Electrical environment

    Input voltage, phase configuration, upstream protection, earthing arrangement and available floor area.

  5. Monitoring & integration

    Which system must see the UPS — BMS, DCIM, NOC — over which protocol, with which alarm set.

Huawei eKit — branch & SMB ICT

A portfolio built to be sold in kits, not projects

eKit is Huawei's product line for small and medium businesses and branch sites: pre-packaged, simple to specify and manageable from a single app — the practical opposite of a 400-page enterprise datasheet.

Switching

Access and PoE switching for branch cabinets — the PoE budget drives the CCTV and Wi-Fi count, so we model it before quoting.

S1730S / S310 class access switches.

Routing & internet edge

Branch routers with VPN, firewall basics and dual-WAN failover — enough to keep a site online without a CCIE on the payroll.

AR-series branch routers.

Wi-Fi

Wi-Fi 6 access points with cloud or local management — sized on a real site survey for coverage and capacity, not on a room count.

AirEngine series access points.

CCTV & recording

IP cameras and NVRs for retail, warehouses and small buildings, with storage and retention calculated per camera.

Branch power

A UPS sized for the branch cabinet, quoted with the switch and the APs so the runtime matches what is actually in the rack.

One management plane

eKit management from an app: onboarding, configuration templates and firmware across every site you have deployed.

The whole ELV package

What else we supply around the power and the network

One order, one delivery note, one warranty contact. Where a brand is added by project, we tell you before you ask which lines we hold and which we source.

Structured cabling & containment

Copper and fibre, patch panels, trays and cabinets — specified with the active equipment so port counts and PoE budgets match.

Access control & intercom

Controllers, readers, locks and door hardware, with the power supply and lock-side wiring included rather than assumed.

CCTV & video

Cameras, NVRs and storage sized for the retention the client actually requires, with bandwidth modelled on the network plan.

Audio-visual & meeting rooms

Displays, room systems and control, integrated with the room automation on the AI side of our portfolio.

Public address & voice alarm

PA/VA where it falls inside the ELV scope, with the civil-defence documentation path built into the schedule.

Smart lighting & sensors

Occupancy, daylight and scene control that connects to the BMS and to the room platform above it.

Practical questions

What integrators ask about our ELV portfolio

Do you hold UPS stock in the UAE?
We hold stock across the fast-moving ratings and configurations and release it against firm orders. Factory-order configurations carry the manufacturer lead time, stated per line on the quotation so you can plan the programme rather than average it.
Can you size the UPS for us from a drawing?
Yes, and it is the part of the job we would rather do ourselves. Send the single-line diagram or the load schedule and we return a sizing sheet with the assumed diversity, runtime and battery type visible, so your consultant can challenge it.
What warranty and service cover applies?
Warranty terms follow the manufacturer's standard for the model and territory; extended cover and on-site response options are available and quoted separately. We register the units at delivery so the cover starts from the correct date.
Is eKit the same product as the enterprise Huawei portfolio?
No — eKit is a distinct line built for small and medium businesses and branch sites, with its own SKUs, packaging and management app. For larger or more complex sites we would quote from the enterprise portfolio instead, and we say so rather than fitting eKit where it does not belong.
Can you supply batteries and spares years later?
We track the installed base and can supply replacement batteries, modules, fans and option cards for the units we have supplied. Ask for a spares list with the original order so the part numbers are recorded while they are current.

Send the load schedule. Get a sized unit back.

Connected load, runtime, redundancy and floor area — four numbers are enough for us to start. We will come back with a configuration and availability.